Hanna Instruments pH & Water Analysis Electrode Storage Solution

RS Stock No.:
3751874
Mfr. Prt No.:
HI-70300
Brand:
Hanna Instruments

Technical Reference

Legislation and Compliance

RoHS Status: Not Applicable

Statement of Conformity

RS Components
Statement of Conformity

This statement confirms that the product detailed below complies with the specifications currently published in the RS media and has been subject to the strict quality conditions imposed by RS Components’ internal management systems. Furthermore and where applicable, it confirms that all relevant semiconductor devices have been handled and packed under conditions that meet the administrative and technical requirements of ANSI/ESD S20.20 and EN61340-5-1 electrostatics control standards.

Compliant Product Details
RS stock number 3751874
Product description Hanna Instruments pH & Water Analysis Electrode Storage Solution
Manufacturer / Brand Hanna Instruments
Manufacturer part number HI-70300

The foregoing information relates to product sold on, or after, the date shown below.

RS COMPONENTS

Date Apr 18, 2024

RS Components Pte Ltd Robinson Road, P.O. Box 1582, Singapore 903132


Product Details

Hanna Instruments pH & Water Analysis Electrode Cleaning and Storage Solutions

Accessories for Electrodes, Hanna Instruments offer solutions ideal for maintenance, calibration and storage. Made with chemicals that are traceable and conform to international standards. Preventing premature failure and reliable and accurate pH measurement their cleaning and storage solutions are of high quality.

Cleaning Solution:

Used for cleaning the liquid junction of electrodes, regular maintenance with this cleaning solution prevents clogging which often leads to inaccurate readings. Containing Hydrochloric Acid 0.034%, protective equipment should be used as per the manufacturers guidelines. Supplied in a 460ml bottle.

Storage Solution:

Used to store the glass probes and re-calibrate meters, the storage solution is a buffer with antibacterial properties. This solution is prepared with high grade Potassium Chloride and Potassium hydrogen Phthalate by titration with NIST 2201 standardised Silver Nitrate and NIST 84j standardised Sodium Hydroxide Solution respectively. Supplied in a 460ml bottle.

Note: Never store Electrodes in distilled or deionized water.

Frequently asked questions:

How often should you clean Electrodes?

Hard waters, viscous and dirty samples are two of the many reasons Electrodes need regular cleaning. Cleaning should be a regular preventative maintenance procedure to prevent premature electrode failure, ideally once a day or at least once per week. Maintenance should be carried out regularly or as soon as build up has been detected.

How to know if an Electrode needs cleaning:

Noise - If readings fluctuate the junction could be clogged or dirty and may need cleaning.

Dry Membrane/Junction or Low Slope - The Electrode will need soaking in a storage solution.

No Slope - If the pH meter reads the same value constantly there could be cracks and an electrode replacement would be needed as apposed to cleaning.

Slow Response/Excessive drift - The tip will need soaking in a cleaning solution, and then a storage solution to re-calibrate the meter.

Always follow manufacturers instructions for Electrode cleaning and storage.


Specifications

Attribute Value
Brand Hanna Instruments
Accessory Type Storage Solution
For Use With Electrode
Checking stock...
VND
1,137,423.35
Out of stock
Price Each
Unit(s)Per Unit(VND)
11,137,423.35
*price per unit indicative
"Hanna Instruments pH & Water Analysis Electrode Storage Solution" added to the basket

Need help to find products?
Contact us now We'll get back to you shortly



Bạn có cần sự giúp đỡ?
Liên hê ngay Để nhận sự hỗ trợ bằng tiếng việt


Related products